MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
6.4 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
4000.0 pounds per square inch gage
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1750.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Vertical
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Counterclockwise
MRC:
The design of a rotary pump as determined by the mechanical principle used to achieve movement of the fluid.AHZR
Rotary Pump Design:
Gear
MRC:
The means by which the item is operated.AHZT
Operation Method:
Powered
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Key type, external
MRC:
The length of a straight line which passes through the center of the drive shaft end,and terminates at the circumference.AJAC
Drive Shaft End Diameter:
0.985 inches
MRC:
A measurement of the distance the drive shaft extends from the housing.AJAD
Drive Shaft Length:
1.653 inches