부품 정보
Ups, 3kva 220vac; ups for shipboard applications
TXT
묘사:
Uninterruptible Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
23.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.200 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ups assembly, 3kva ups/ebm/3-bkr pdu, 220v
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
220.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
3.0 ac kilovolts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz and 60.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
45.0 hertz and 65.0 hertz single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.0 to 40.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
16.0 ac amperes single power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
5.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Run-time can be extended with upt to 3 hot-swappable extended battery modules; has graphical lcd with blue lacklight; 4 status-indicating leds; emergfull system self-test diagnostics; remote emergency power-off