Electronic Frequency Converter
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+5.0/+55.0
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
0.02 inches total excursion
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
15.0
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-4 acft; an/mpm=54
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Electron tube
MRC:
The shift of the frequency of the item.BHSZ
Frequency Shift:
10.3 gigahertz
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.3 gigahertz operating channel
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Stepped
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
2.0
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
2.0 decibels
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
11.0 milliseconds