부품 정보
For j-85 engines with noncenter vent oil systems
TXT
묘사:
Vertical Tube Manometer
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
350.0 pounds per square inch
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
3 overflow check valves
MRC:
An indication of whether or not an adjuster to return the item to zero is provided.ANTC
Zero Adjuster:
Provided
MRC:
An indication of the scale range.APSK
Scale Range:
+0.000/+1.000 inches and +0.000/+8.000 pounds per square inch
MRC:
Indicates the type of receptacle provided.ATMG
Receptacle Type:
Well
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
0.200 inches and 0.100 pounds
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded
MRC:
Indicates the type of facility(ies) provided to connect the item.BDGB
Connection Facility Type:
External
MRC:
Indicates the connection location.BGRY
Connection Location:
Back, center
MRC:
An indication of whether or not a feature for eliminating parallax is provided.BHMM
Parallax Eliminating Feature:
Provided
MRC:
The indicating liquid for which the item is designed.BHMN
Indicating Liquid For Which Designed:
Mercury
MRC:
An indication of whether or not indicating liquid is provided.BHMP
Indicating Liquid:
Not provided
MRC:
An indication of whether or not a control valve is provided.BHMQ
Control Valve:
Provided
MRC:
An indication of whether or not an equalizing valve is provided.BHMR
Equalizing Valve:
Not provided
MRC:
An indication of the mounting provision for which the item is designed.BHMS
Mounting Provision For Which Designed:
Surface panel
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.THDS
Thread Size And Series/type Designator:
0.250-18 npt