TXT
묘사:
Electronic Chopper
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
3 and 1
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Flexible lead and tube plug
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.016 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.845 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+100.0 degrees celsius
MRC:
Indicates the type of coil used.APAG
Coil Type:
Isolated
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, double throw
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
8.0 ac pounds per hour dry and 9.6 ac pounds per hour with retaining chain
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
Indicates the type of base furnished with the item.AWET
Base Type:
Standard base
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Provided
MRC:
The amount of input current for which the item is rated.AZSL
Input Current Rating:
38.0 milliamperes
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Equal
MRC:
An indication of whether the drive current is the same as,or diffrent from,the input current.BGRD
Drive Current Relationship To Input Current:
Equal
MRC:
An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
Output/input Voltage Relationship:
Equal
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
10.0 dc pounds per hour with retaining chain
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
1.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
56.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
Between 155.0 and 185.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Provided
MRC:
The size designation of the mounting base as it is commercially known and/or identified.BGRT
Base Mounting Size Designation:
Std 4 pin tube base size
MRC:
An indication of the arrangement of the terminal pattern.BGRW
Terminal Pattern Arrangement:
Must mate w/standard 4 pin minature socket
MRC:
Indicates the connection location.BGRY
Connection Location:
Ac coil connection at top