TXT
묘사:
Radio Frequency Coil
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
1/4 single component single winding
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Air wound single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.720 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.040 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.460 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component single winding
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Tinned wire leads
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.04030 inches american wire gage single component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
200.0 milliamperes dc single component single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead