부품 정보
						Udwg title: cable assembly,  sp,  elec,  rapid message processing set j1 (black). Hci cable is 60854 c003462-03. Hci connector backshell is 60854 c003452-02. Emi gasket is 60854 c005585-01. The connectors are hci and hci processes apply.
					 
				 
						
			
			
							
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
					 
					
						Cross Sectional Shape:
					
					
						Round					
				 
							
					
						MRC:
						A measurement of the longest dimension of an item,in distinction from width.AAJU
					 
					
						Overall Length:
					
					
						79.500 inches					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Lgm 30g					
				 
							
					
						MRC:
						Indicates the type of facility provided on the device for attaching to another item.AKRZ
					 
					
						Termination Type:
					
					
						Connector external angle 1st end all conductors					
				 
							
					
						MRC:
						Indicates the type of facility provided on the device for attaching to another item.AKRZ
					 
					
						Termination Type:
					
					
						Connector plug 2nd end all conductors					
				 
							
					
						MRC:
						The number of electrical conductors included on the item.AMQN
					 
					
						Conductor Quantity:
					
					
						38					
				 
							
					
						MRC:
						The number of strands per conductor.BLNZ
					 
					
						Strand Quantity Per Conductor:
					
					
						19 all conductors					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Agav					
				 
							
					
						MRC:
						The fabricated form of the conductor.CXCW
					 
					
						Conductor Form:
					
					
						Stranded all conductors					
				 
							
					
						MRC:
						The designation used to describe the round stranded or round solid conductor size.CXDC
					 
					
						Round Conductor Size:
					
					
						22 awg all conductors					
				 
							
					
						MRC:
						The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
					 
					
						Strand Awg Size Per Conductor:
					
					
						34 all conductors					
				 
							
					
						MRC:
						The arrangement and number of arrangements of the conductors.CXDQ
					 
					
						Conductor Arrangement And Quantity:
					
					
						19 twisted pair					
				 
							
					
						MRC:
						The number of groups into which two or more conductors are arranged.CXDT
					 
					
						Group Quantity:
					
					
						19					
				 
							
					
						MRC:
						Indicates the type and number of conductor arrangements within groups.CXDY
					 
					
						Conductor Grouping Arrangement Type And Quantity:
					
					
						1 twisted pair all groups					
				 
							
					
						MRC:
						The identification of the conductors within a group.CXFG
					 
					
						Conductor Sequence Within Groups:
					
					
						Fifth conductor third group and sixth conductor third group					
				 
							
					
						MRC:
						The identification of the conductors within a group.CXFG
					 
					
						Conductor Sequence Within Groups:
					
					
						First conductor first group and second conductor first group					
				 
							
					
						MRC:
						The identification of the conductors within a group.CXFG
					 
					
						Conductor Sequence Within Groups:
					
					
						Ninth conductor fifth group and tenth conductor fifth group					
				 
							
					
						MRC:
						The identification of the conductors within a group.CXFG
					 
					
						Conductor Sequence Within Groups:
					
					
						Seventh conductor fourth group and eighth conductor fourth group					
				 
							
					
						MRC:
						The identification of the conductors within a group.CXFG
					 
					
						Conductor Sequence Within Groups:
					
					
						Third conductor second group and fourth conductor second group					
				 
							
					
						MRC:
						The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
					 
					
						Terminal Manufacturer Identifying Reference Number:
					
					
						C003463-05 1st end all conductors					
				 
							
					
						MRC:
						The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
					 
					
						Terminal Manufacturer Identifying Reference Number:
					
					
						D38999/46wj35pc 2nd end all conductors					
				 
							
					
						MRC:
						The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
					 
					
						Terminal Commercial And Government Entity Code:
					
					
						60854 1st end all conductors					
				 
							
					
						MRC:
						The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
					 
					
						Terminal Commercial And Government Entity Code:
					
					
						81349 2nd end all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper 3rd position shield braid,  metallic all groups					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper 5th position shield braid,  metallic cable					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper 7th position shield braid,  metallic cable					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper core conductor all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic polyimide 2nd position jacket all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic polyvinyl chloride 1st position primary insulation all conductors					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic polyvinyl chloride 4th position jacket all groups					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic polyvinyl chloride 8th position jacket cable					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic polyester 6th position shield foil cable					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
					 
					
						Material Specification:
					
					
						Astm b33 assn standard single material response core conductor all conductors					
				 
							
					
						MRC:
						An indication of the nuclear hardness criticality of the item.NHCF
					 
					
						Nuclear Hardness Critical Feature:
					
					
						Hardened					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Tin 5th position shield braid,  metallic cable					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Tin 3rd position shield braid,  metallic all groups					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Tin 7th position shield braid,  metallic cable					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Tin core conductor all conductors					
				 
							
					
						MRC:
						The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
					 
					
						Surface Treatment Specification:
					
					
						Astm b33 assn standard single treatment response core conductor all conductors					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						External angle and external straight connector