부품 정보
Provides connection and distriubtion facilities for appropriate additional test equipment
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
14.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Test panel; rf field simulator; loop cable coupler; loop cable assembly; sense antenna cable; cable harness; frequency meter
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Yaircraft radio corporation and aircraft radio corporation and aircraft radio corporation andaircraft radio corporation and aircraft radiocorp and aircraft radio corporation and aircraft radio corporation and aircraft radio corpand aircraft radio corporation and aircraft radio corp
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
19770 part no. And 19780 drawing no. And 19760 part no. And 17085 part no. And 17984 part no. And 197900 part no. And 1949 part no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Alignment of receiver; measurementof ac and dc component; input and output voltages; measurement of loop compensation; measurement of loop sensitivity; measurement of power supply; operational check for comp and loop operation ofan an/arn-59 system; operational check of all control unit functions; operational check of indicator; provide rf field to energize; loop and sense antenna input; signal to energize receiver
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Tests adf receiving set in frequency range of 190 to 1750 kc