부품 정보
Weapon system essential
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
460.0 ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Wasp class lhd, tarawa class lha, iwo jima class lph, emory s. Land class as, mars class t-afs 1, wichita class aor.
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, both positions maintained single switch unit
MRC:
The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
Switch Release Force:
0.5 ounces
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The amount of force required to actuate the switch.CSJN
Switch Actuating Force:
5.0 ounces
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
Between 0.093 pretravel inches and 0.062 overtravel inches and 0.030 differential inches
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
10.000 amperes resistive ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 tab, solder lug