TXT
묘사:
Centrifugal Pump Unit
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Fuel system onboard 378 ft whec coast guard vessels
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
5.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
65.0 pounds per square inch gage
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
150.000 feet
MRC:
The vertical distance from the level of supply to the center of the pump.AHYY
Suction Lift:
150.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1750.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Double
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
1.250-11-1/2 npt