부품 정보
Relays have captive clamp terminals fully accessible from the front, a molded coil with low operating temperature, and silver alloy contacts suitable for low voltage circuits; contacts feature the exclusive knife-edge design which provides a "self-wiping" action on every closure
TXT
묘사:
Electromagnetic Relay
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Switchboard, mn prop, p/n 1648a34g06, used onboard 400 ft wagb coast guard vessels
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
1.5 amperes dc all windings
MRC:
The highest voltage at which the auxiliary contacts are rated for normal operation,expressed in volts.CSQC
Auxiliary Contact Maximum Voltage Rating In Volts:
138.0 dc
MRC:
The lowest net amount of the specified energizing electrical characteristic necessary for the normal functioning of the relay. the net value being the difference between multiple or opposed input elements during normal operation.CTCN
Minimum Differential Electrical Operating Rating:
12.0 volts
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
250.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw all functions