TXT
묘사:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b first flange all connection facilities
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand first flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.2786 inches first flange and 0.2814 inches first flange
Flange Inside Height:
0.1386 inches first flange and 0.1414 inches first flange
Flange Inside Height:
0.222 inches second flange and 0.224 inches second flange
Flange Outside Width:
0.745 inches second flange and 0.755 inches second flange
Flange Outside Width:
0.735 inches first flange and 0.765 inches first flange
Flange Outside Height:
0.745 inches second flange and 0.755 inches second flange
Flange Outside Height:
0.735 inches first flange and 0.765 inches first flange
Flange Inside Diameter:
0.485 inches first flange and 0.515 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.182 inches second flange and 0.192 inches second flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.116 inches second flange all connection facilities and 0.118 inches second flange all connection facilities
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.20
Waveguide Outside Width:
Between 0.358 inches and 0.362 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches first flange all connection facilities
Waveguide Inside Width:
Between 0.2785 inches and 0.2815 inches
Waveguide Inside Height:
Between 0.1385 inches and 0.1415 inches
Waveguide Outside Height:
Between 0.218 inches and 0.222 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 threaded hole first flange all connection facilities
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole second flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Choke type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
Waveguide Length:
Between 20.121 inches and 20.129 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment and flange
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
All tubing surfaces gold and all tubing surfaces silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold and silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Any acceptable all tubing segment and flange outside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver single tubing segment inside surfaces and gold single tubing segment inside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight type
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equip.