TXT
묘사:
Flow Control Thermostat
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.125 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Flange
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
By-pass
MRC:
The length of a straight line which passes through the center of the largest diameter of an item,and terminates at the outside circumference.AGWM
Largest Outside Diameter:
Between 2.485 inches and 2.495 inches
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
For engine cooling system
MRC:
The measured distance the valve travels.AMSD
Valve Travel Distance:
0.406 inches
MRC:
Indicates the type of thermostat.AWPA
Thermostat Type:
Bimetallic
MRC:
The rated temperature at which the item starts to open.AWTM
Opening Tempurature Rating:
Between 145.0 degrees fahrenheit and 150.0 degrees fahrenheit
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 175.0 degrees fahrenheit and 185.0 degrees fahrenheit
MRC:
An indication of whether or not a spring operated pressure relief is provided.AWTP
Spring Operated Pressure Relief:
Not provided
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Engine