MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Crimped (tube) 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Crimped (tube) 2nd end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Crimped (tube) 3rd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.469 inches 2nd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.469 inches 3rd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
0.703 inches 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 3rd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 1st end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.125 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.125 inches 3rd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.625 inches 1st end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.050 inches 2nd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.050 inches 3rd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.060 inches 1st end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy