					Power Transformer				
			 
			
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.370 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						3.190 inches  all mounting facilities single center group					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						3.130 inches  all mounting facilities single center group					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.190 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.750 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
					 
					
						Mounting Slot Width:
					
					
						0.460 inches  single group					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						50.000 hertz  single component					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						60.000 hertz  all components					
				 
							
					
						MRC:
						The relationship of the phase input to the phase output of an alternating current.ACZC
					 
					
						Input-output Phase Relationship:
					
					
						Single phase to single phase single component					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						105.0 degrees celsius					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						F-15 support equipment					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						4 single group					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Slot single group					
				 
							
					
						MRC:
						The amount of operating current for which the winding is designed.CRBZ
					 
					
						Winding Operating Current:
					
					
						1.3 amperes ac  single component 1st secondary					
				 
							
					
						MRC:
						The amount of operating current for which the winding is designed.CRBZ
					 
					
						Winding Operating Current:
					
					
						6.2 amperes ac  single component 2nd secondary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						208.00 ac pounds per hour wet single component 1st primary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						230.00 ac pounds per hour wet single component 2nd primary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						460.00 ac pounds per hour wet single component 3rd primary					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 screw