MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
280.0 degrees fahrenheit single response
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Compressor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Swivel nut, inverted flar (tube) all ends
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal tube all ends
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
500.0 pounds per square inch single response
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
0.500 inches all ends
MRC:
The face to face distance.CWCF
Face To Face Distance:
5.00 inches
Center To Center Distance:
2.50 inches
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Liquid single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight thru