TXT
묘사:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.120 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.830 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.190 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.060 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.156 inches single mounting facility
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
60.0
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
140.0 ohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole single mounting facility
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Polarized
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
In-line single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
Operating Current Rating And Type:
1.19 milliamperes dc single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 pin all functions