TXT
				
				
					묘사:
				
				
					Variable Attenuator				
			 
			
							
										
					
						MRC:
						The primary application for which the item is designed.AAFS
					 
					
						Application Design:
					
					
						Transmission line					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Coaxial type					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						Between 2.470 inches and 2.530 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						0.660 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						0.840 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						Between 0.470 inches and 0.530 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.720 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						Between 0.084 inches and 0.104 inches 					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Radar set an/mpn-14k					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.50					
				 
							
					
						MRC:
						A letter or group of letters used to designate the particular coaxial connector series.AHUC
					 
					
						Coaxial Connector Series Designation:
					
					
						Sma					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.AJDB
					 
					
						Power Rating:
					
					
						2.0 watts average					
				 
							
					
						MRC:
						The mathematical relationship of power available at the load before and after addition of the item to the circuit,set to its lowest value of attenuation,expressed in maximum decibels.ASYC
					 
					
						Insertion Loss At Minimum Attenuation In Maximum Decibels:
					
					
						0.5					
				 
							
					
						MRC:
						The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
					 
					
						Overall Attenuation Range In Decibels:
					
					
						+0.0/+20.0					
				 
							
					
						MRC:
						The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
					 
					
						Attenuation Variation Method:
					
					
						Stepped					
				 
							
					
						MRC:
						The number of intervals at which the item can be set.ASYG
					 
					
						Step Position Quantity:
					
					
						4					
				 
							
					
						MRC:
						The amount of attenuation between adjacent steps,expressed in decibels.ASYH
					 
					
						Attenuation Per Step In Decibels:
					
					
						10.0 and 15.0 and 20.0					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 unthreaded hole					
				 
							
					
						MRC:
						The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
					 
					
						Frequency Range:
					
					
						Between 1.000 gigahertz and 8.000 gigahertz 					
				 
							
					
						MRC:
						The minimum and maximum limits of attenuation within the overall attenuation range for which a related accuracy value has been specified,expressed in decibels.BQNS
					 
					
						Segment Attenuation Range In Decibels:
					
					
						+0.00/+10.00 and +10.00/+15.00 and +15.00/+20.00					
				 
							
					
						MRC:
						Indicates the type and number of facilities for adjusting the item.CQTQ
					 
					
						Adjustment Device Type And Quantity:
					
					
						1 slotted screw					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position rectangular					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 connector,  coaxial,  female