부품 정보
3/4 in. Npt stainless steel inlet and drain, stainless steel tank cover with guides and handle, power densi type 65.8 w/gal of solution
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
12.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
15.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
200.0 degrees fahrenheit
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
11.000 inches
MRC:
A numeric value which represents the number of devices that convert energy from one form to another.AKVR
Transducer Quantity:
4
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
30 min. Timer 1, power cord 1, handbook 1
MRC:
The electrical voltage value for which the generator is rated.ALSP
Generator Voltage Rating:
115.0
MRC:
The number of alternating current phases of the generator.ALSR
Generator Phase:
Single
MRC:
The cycles per second (hertz) of the generator alternating current.ALSS
Generator Frequency Rating:
60.0
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Nonportable
MRC:
Indicates the design type of the item.APGF
Design Type:
Ultrasonic
MRC:
Indicates the type of current of the generator,whether alternating,direct,or both.BCPD
Generator Current Type:
Ac
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrically
MRC:
An indication of whether or not an electric motor is included.BMWX
Electric Motor:
Not included
MRC:
Indicates the capacity of the tank.BSSM
Tank Capacity:
8.0 gallons
MRC:
The value of electrical input power for which the generator is rated.BWWR
Err Default:
Err default
MRC:
The value of electrical output power for which the generator is rated.BWWS
Generator Output Power Rating:
700.000 watts
MRC:
The range of complete cyclic changes,per unit of time,for which the generator output is rated.BWWT
Err Default:
Err default
MRC:
The means by which the generator is cooled.BWWW
Generator Cooling Method:
Forced air
MRC:
The distance measured in a straight line from the bottom to the top of the generator.BWWX
Err Default:
Err default
MRC:
An overall measurement taken at right angles to the length of the generator,in distinction from thickness.BWWY
Err Default:
Err default
MRC:
An overall measurement between specified points of the generator,in distinction from height.BWWZ
Err Default:
Err default
MRC:
An indication of whether or not a solvent reconditioner is included.BWXD
Solvent Reconditioner:
Not included
MRC:
An indication of whether or not a spray cleaning provision is provided.BWXF
Spray Cleaning Provision:
Not provided
MRC:
An indication of whether or not an auxiliary solvent supply is included.BWXG
Auxiliary Solvent Supply:
Not included
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
120.0 ac
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0