MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
35.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
35.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 108.0 volts and 121.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 21.5 volts and 29.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 300.0 hertz and 420.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Junction box; vibration isolator; control indicator; cable
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 11
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Sperry gyroscope co
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
1509963 part no. And 334286 part no. And 1510030 part no. And 1510031 part no. And 1510032 part no. And 1510033 part no. And 1510034 part no. And 1510035 part no. And 1510036 part no. And 1510037 part no. And 1510038 part no. And 1510039 part no. And 1510040 part no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Servo dynamic test, signal simulation and generation of amp checkout and alignment
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Input signals, 4.3 kmc porm 5 kmc, 380 to 420 cycles and dc, 455 kc, 395 kc, 30 kc, 60 kc and 300 cycles, servo dynamic test signal, 400 cycles by 0.015 cycles, 455 kc linear wideband amplifier and detector, o/a gain, 54 db porm 1 db
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-9.3
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
37.000 inches
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
1. Test set, radar, except specially designed