TXT
묘사:
Radio Frequency Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.218 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.500 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
3
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
Am2123au-80058
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Partially enclosed
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Module
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state and electron tube
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
100.0 kilohertz operating channel and 1.0 megahertz operating channel
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
1.000 megohms output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 milliohms input channel err-100
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
400.0 2nd voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 1st voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single