TXT
묘사:
Metallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
0.391 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit single response and 450.0 degrees fahrenheit single response
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.890 inches
MRC:
The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
Minimum Inside Bending Radius:
4.620 inches
MRC:
The amount of rotation in a counterclockwise direction needed to bring the centerline of one rigid elbow into coincidence with the centerline of the rigid elbow on the opposite end,expressed in degrees.ADKX
Angle Between Rigid Elbow Fittings In Deg:
0.0
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Boeing helicopter, h46
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Elbow 1st end
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Identical ends
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
8000.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
1500.0 pounds per square inch
MRC:
The angle of the end surface upon which the mated surface seats.CQRB
Seat Angle:
37.0 degrees 1st end
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
3000.0 pounds per square inch
MRC:
The angle that the flow is turned from the straight flow.CRFY
Flow Angle:
90.0 degrees 1st end
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
21.500 inches working