부품 정보
Low cost, dc to 500 mhz, 92 db logarithmic amplifier
TXT
묘사:
Digital Microcircuit
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 5.800 inches and 6.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 1.350 inches and 1.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.800 inches and 4.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 4.800 inches and 5.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 1.100 inches and 1.650 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+85.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+125.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Conversion of signal level to decibel form; transmitter antenna power measurement; receiver signal strength indication (rssi); low cost radar ad sonar signal processing; network and spectrum analyzers (to 120 db); signal level determination down to 20 hz; true decibel ac mode fpr multimeters
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
1 amplifier, log
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Complete multistage logaritmic amplifier; 92 db dynamic range, -75 dbm to +17 dbm to -90 dbm using matching network; single supply of 2.7 v at 7.5 ma typical; dc to 500 mhz operation, +/-1 db linearity; slope of 25 mv/db, intercept of -84 dbm; highly stable scaling over temperature; fully differential dc-coupled signal path; 100 ns power-up time