MRC:
The ability of an item to withstand a specified torque load without fracture.AAPL
Torque Load Rating:
8.50 inch-ounces
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.656 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.063 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.531 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. An/arn-7
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 4-40 tapped mtg holes on 1-23/64 in. By 1 in. Mtg centers
MRC:
The basic structure of the item.ALXF
Structural Design:
Nonpile-up
MRC:
The operating current for which the item is rated.APAM
Operating Current Rating:
2.000 amperes
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
3
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
3
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
3.700 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
105.000 milliamperes
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Counterclockwise
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
8.000 ohms
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
Spdt
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
2
MRC:
The amount of direct current resistance required to activate the coil pull-in.CPWP
Coil Pull-in Dc Resistance Rating:
7.500 ohms
MRC:
The amount of direct current resistance required to maintain operation of the coil hold-in.CPWQ
Coil Hold-in Dc Resistance Rating:
260.000 ohms
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
30.000