측정 단위:
* special requirements. EA
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
40.000 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Unthreaded
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
7.125 inches
MRC:
The length of a straight line which passes through the center of the outlet,and terminates at the inside circumference.AJLW
Outlet Inside Diameter:
4.000 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Dry
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Air
MRC:
The basic design of the muffler.ARND
Muffler Design:
Straight through
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal
MRC:
The location of the inlet.ARNJ
Inlet Location:
Centrally in end sect of body
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
4.000 inches
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the outside circumference.ARSQ
Inlet Outside Diameter:
4.125 inches
MRC:
The length of a straight line which passes through the center of the inlet,with terminated points on the inside circumference.ARTE
Inlet Inside Diameter:
4.000 inches
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Unthreaded
MRC:
The location of the outlet.ARTJ
Outlet Location:
Centrally in end sect of body
MRC:
A measurement of the longest dimension of the outlet projection,in distinction from width.ARTK
Outlet Projection Length:
4.000 inches
MRC:
The length of a straight line which passes through the center of the outlet,with terminated points on the outside circumference.ARWA
Outlet Outside Diameter:
4.125 inches
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
6 slotted err-100
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
6 slotted
MRC:
Indicates the location/s/ of the nonconnection outlet on the item.ARXZ
Nonconnection Outlet Location:
On circ
MRC:
Designates the size of the nonconnection outlet included on the item.ARYA
Nonconnection Outlet Size:
1-1/4 in. Lg by 1/8 in. W
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Aluminum
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Engine exhaust system, non-aircraft