MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Hole mounted					
				 
							
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Dustproof					
				 
							
					
						MRC:
						The measurement of the distance that the actuator protrudes from the body.AFGK
					 
					
						Actuator Length:
					
					
						0.875 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
					 
					
						Actuator Style:
					
					
						Rectangular					
				 
							
					
					
						Actuator Height:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
					 
					
						Actuator Width:
					
					
						0.750 inches 					
				 
							
					
					
						Housing Height:
					
					
						1.312 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of a housing,in distinction from thickness.AFWE
					 
					
						Housing Width:
					
					
						0.875 inches 					
				 
							
					
					
						Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
					
					
						1.375 inches 					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						125.0 ac					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole,  single throw,  normally open,  momentary action single switch unit					
				 
							
					
						MRC:
						The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
					 
					
						Switch Release Force:
					
					
						3.0 ounces 					
				 
							
					
						MRC:
						The amount of force required to actuate the switch.CSJN
					 
					
						Switch Actuating Force:
					
					
						14.0 ounces 					
				 
							
					
						MRC:
						The movement of the switch actuator.CXQQ
					 
					
						Actuator Movement:
					
					
						Between 0.062 overtravel inches and 0.001 differential inches 					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						10.000 amperes resistive ac					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 tab,  solder lug