TXT
묘사:
Flow Control Thermostat
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.094 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Flange
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Choke
MRC:
The length of a straight line which passes through the center of the largest diameter of an item,and terminates at the outside circumference.AGWM
Largest Outside Diameter:
2.500 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
1 gasket, valve seat
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Cool engine operation
MRC:
The measured distance the valve travels.AMSD
Valve Travel Distance:
0.406 inches
MRC:
Indicates the type of thermostat.AWPA
Thermostat Type:
Bellows
MRC:
The rated temperature at which the item starts to open.AWTM
Opening Tempurature Rating:
180.0 degrees fahrenheit
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
200.0 degrees fahrenheit
MRC:
An indication of whether or not a spring operated pressure relief is provided.AWTP
Spring Operated Pressure Relief:
Not provided
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Radiator, cooling system, engine, non aircraft