TXT
				
				
					묘사:
				
				
					Safety Relief Valve				
			 
			
										
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Disk					
				 
							
					
						MRC:
						Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
					 
					
						Bonnet Type:
					
					
						Exposed spring					
				 
							
					
						MRC:
						The means by which the bonnet is attached to the item.ADST
					 
					
						Bonnet Attachment Method:
					
					
						Bolted					
				 
							
					
						MRC:
						The means of closing the item when inlet pressure decreases.ADSU
					 
					
						Disk Loading Method:
					
					
						Spring					
				 
							
					
						MRC:
						The rated valve discharge capacity per unit of time.ADSY
					 
					
						Valve Discharge Flow Rate:
					
					
						32700.0 pounds per hour					
				 
							
					
						MRC:
						Indicates the type of renewable seating ring in the item.ADZH
					 
					
						Renewable Seat Ring Type:
					
					
						Threaded					
				 
							
					
						MRC:
						The number of bolt holes provided on the item.AECS
					 
					
						Bolt Hole Quantity:
					
					
						8 1st end					
				 
							
					
						MRC:
						The number of bolt holes provided on the item.AECS
					 
					
						Bolt Hole Quantity:
					
					
						8 2nd end					
				 
							
					
						MRC:
						The means used to control the operation of the valve.AQLR
					 
					
						Valve Operation Method:
					
					
						Automatic or manual					
				 
							
					
						MRC:
						The physical configuration of the flange.ARKN
					 
					
						Flange Shape:
					
					
						Round with holes 1st end					
				 
							
					
						MRC:
						The physical configuration of the flange.ARKN
					 
					
						Flange Shape:
					
					
						Round with holes 2nd end					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Pressure tight outlet side					
				 
							
					
						MRC:
						Designates the size of the valve.CCFG
					 
					
						Valve Size:
					
					
						2.500 inches					
				 
							
					
						MRC:
						The predetermined pressure at which the item is calibrated to open.CSDC
					 
					
						Opening Pressure Setting:
					
					
						725.0 pounds per square inch					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
					 
					
						Outside Diameter:
					
					
						7.500 inches 1st end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
					 
					
						Outside Diameter:
					
					
						9.000 inches 2nd end					
				 
							
					
						MRC:
						A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
					 
					
						Thickness:
					
					
						1.125 inches 2nd end					
				 
							
					
						MRC:
						A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
					 
					
						Thickness:
					
					
						1.188 inches 1st end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
					 
					
						Bolt Hole Diameter:
					
					
						0.875 inches 1st end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
					 
					
						Bolt Hole Diameter:
					
					
						0.875 inches 2nd end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
					 
					
						Bolt Circle Diameter:
					
					
						5.875 inches 1st end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of the bolt circle,and terminates at the circumference.CWCT
					 
					
						Bolt Circle Diameter:
					
					
						7.250 inches 2nd end					
				 
							
					
						MRC:
						The design of the flange face.CWDF
					 
					
						Flange Face Design:
					
					
						Raised straight 2nd end					
				 
							
					
						MRC:
						The design of the flange face.CWDF
					 
					
						Flange Face Design:
					
					
						Recessed straight 1st end					
				 
							
					
						MRC:
						A nominal measurement from the bottom to the top surface of a raised face,in distinction from depth.CWDH
					 
					
						Raised Face Height:
					
					
						0.062 inches 2nd end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of a raised face,and terminates at the circumference.CWDL
					 
					
						Raised Face Diameter:
					
					
						5.500 inches 2nd end					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of the recess,and terminates at the circumference.CWDP
					 
					
						Recess Diameter:
					
					
						6.875 inches 1st end					
				 
							
					
						MRC:
						A nominal measurement between specified points on the recess,in distinction from height.CWDS
					 
					
						Recess Depth:
					
					
						0.062 inches 1st end					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Angle flanged ends					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						As differentiated by the valve discharge flow rate requirement