TXT
				
				
					묘사:
				
				
					Radio Frequency Interfere Filter				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						5.250 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						5.000 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						2.250 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						2.750 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
					
					
						4.500 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0 to 85.0 degrees celsius					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						6.0 blank					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance blank					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
					 
					
						Input Terminal Manufacturer Code:
					
					
						12143					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
					 
					
						Input Terminal Identification:
					
					
						Pt02e-8-4pw					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
					 
					
						Output Terminal Manufacturer Code:
					
					
						12143					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
					 
					
						Output Terminal Identification:
					
					
						Pt02e-8-4pw					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 threaded hole					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 wire lead input 1st function and 1 connector,  receptacle input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 wire lead output 2nd function and 1 connector,  receptacle output 2nd function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 wire lead input  and 1 connector,  receptacle input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 wire lead output  and 1 connector,  receptacle output 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						120.0 volts ac blank					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular terminal/terminals on two surfaces					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						92400-a31c248 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)