TXT
묘사:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
2 single component single primary output
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
3 single component single primary input
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
15.00 microhenries single component single primary output and 25.00 microhenries single component single primary output
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
15.00 microhenries single component single primary input and 25.00 microhenries single component single primary input
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
2.5 megahertz single component
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Air wound single component
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.500 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.150 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single primary input and winding turns single component single primary input
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single primary output and winding turns single component single primary output
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, fixed autotransformer type single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Color coded lead
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.03196 inches american wire gage single component single primary input
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.03196 inches american wire gage single component single primary output
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
80063-a3132272 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead