부품 정보
Has integral pressure switch to supply fluid on demand when discharge valve is opened or closed, off at 60psi, on at 40psi; environmental protection: corrosion resistant
TXT
묘사:
Reciprocating Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
2
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Diaphragm
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Air to air cooled
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Weapons system bt, engine, aircraft, f100-pw-100 (f-15a/b/c/d)
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
108.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
60.0 pounds per square inch gage
MRC:
The vertical distance from the level of supply to the center of the pump.AHYY
Suction Lift:
6.000 feet
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The reciprocating design of the pump.AHZJ
Pump Reciprocating Design:
Single acting
MRC:
Indicates the type of reciprocating movement within the item.AHZN
Reciprocating Stroke Type:
Fixed
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.55
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
0.375-18 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
0.375-18 npt
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
57.5 watts
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
ITEM-IS-USE-EINA