TXT
묘사:
Electrical Resolver
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Standard round b
MRC:
The length of a straight line which passes through the center of a shoulder,and terminates at the circumference.AAVH
Shoulder Diameter:
Between 0.9995 inches and 1.0000 inches
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 0.6245 inches and 0.6250 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.3980 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
Between 1.0610 inches and 1.0620 inches
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.0930 inches
Undercut Width:
0.0500 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.1195 inches single shaft and 0.1200 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.4370 inches single shaft
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
11
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
10000.0
MRC:
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.AJVF
Phase Shift Angle In Deg:
3.000 input to output
MRC:
The deviation from 90 degrees perpendicularity of the secondary winding,when excitation is applied to one of the primary windings,expressed in minutes.AJVJ
Interaxis Error Angular Range In Minutes:
-6.0/+6.0
MRC:
The limits of permissible deviation of the actual output voltage form the theoretical sinusoidal output voltage divided by the maximum output,expressed in percent.AJVK
Output Voltage Functional Error Range In Percent:
-0.2/+0.2
MRC:
A measurement of the longest dimension of a pilot,in distinction from width.AJWQ
Pilot Length:
0.0620 inches
Shoulder Length:
0.0620 inches
Mounting Surface To Terminal End Distance:
1.7730 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
1.850 rotor to stator
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 screw