TXT
묘사:
Thermostatic Switch
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
84.0 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
2.500 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.366 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube-bulb
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point adjustable, preset and actuation point adjustable, preset
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
-30.00 to 50.00 actuation point degrees fahrenheit and -30.00 to 50.00 deactuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External deactuation point pointer with scale and external actuation point pointer with scale
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
10.00 actuation point degrees fahrenheit and 5.00 deactuation point degrees fahrenheit
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas