MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The length of a straight line which passes through the center of the smallest cross section of a spline,and terminates at the circumference.AAUH
Spline Minor Diameter:
0.791 inches
MRC:
The length of a straight line which passes through the center of the largest cross section of a spline,and terminates at the circumference.AAUJ
Spline Major Diameter:
0.875 inches
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Pad
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
20
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.375 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
4
MRC:
Designates the thread diameter and number of threads per specific measurement scale.ABUJ
Thread Size:
0.437-20
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Splined, straight external
MRC:
The element,compound,or mixture of which the housing is fabricated.AJLF
Housing Material:
Steel
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
Screw Thread Series Designator:
Unf
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise
MRC:
Indicates the location of the thread on the item.APJC
Thread Location:
Internal
MRC:
The number of connections furnished.ASMM
Connection Quantity:
2
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Inlet and outlet
MRC:
The maximum rated working pressure of an item at a specified temperature range.AXFB
Maximum Working Pressure Rating At Specificationified Tempurature Range:
3000psi at minus65 degrees f to plus 350 degrees f
MRC:
The design of the connection.AXFC
Connection Design:
Threaded
MRC:
A measurement of the longest dimension of a spline,in distinction from width.AXFH
Spline Length:
1.375 inches
MRC:
Indicates the displacement type.AXFP
Displacement Type:
Variable
MRC:
The spacing in the arrangement of the mounting bolt holes.AZFG
Mounting Bolt Hole Spacing:
3.750 in. By 3.750 in.
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by the sourc control dwg no.