부품 정보
Truck, fire fighting (quint)
TXT
묘사:
Fire Fighting Truck
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
A measurement of the longest dimension of an item,in distinction from width.ABHQ
Length:
75.000 feet
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Diesel engine
MRC:
Indicates the design type of the item.APGF
Design Type:
Structural
MRC:
The means used to operate the item.APHE
Operation Method:
Hydraulic motor
MRC:
Indicates the type of transmission used to transfer developed mechanical energy to the drive unit.AXJD
Transmission Type:
Automatic
MRC:
Indicates the type of drive provided for the pump.AYJJ
Pump Drive Type:
Power take-off
MRC:
The capacity of the pump.BMGF
Pump Capacity:
1250.0 gallons per minute
MRC:
Indicates the type of pump provided.BRJK
Pump Type:
Centrifugal
MRC:
Indicates the capacity of the tank.BSSM
Tank Capacity:
500.0 gallons
MRC:
An indication of the extinguishing agent for which the item is designed.BTQY
Extinguishing Agent For Which Designed:
Water
MRC:
The number of water tanks provided.BTQZ
Water Tank Quantity:
1
MRC:
An indication of whether or not an aerial ladder/s/ is included.BTRD
Aerial Ladder:
Included
MRC:
A designation indicating the size by which the chassis is commercially known and/or identified.BTRF
Chassis Size Designation:
4x2
MRC:
An indication of whether or not a front wheel drive feature is included.BTRG
Front Wheel Drive Feature:
Not included
MRC:
The design of the cab.BTRL
Cab Design:
Closed
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Red/blue strobe type warning lights; dual forward facing air horns; 100 watt electronic siren with volume control and selection of radio, pa, manual, yelp, wail and hi-lo modes; cab roof mounted spotlights; four scene lights; 500 gal. Baffeled polypropylene water tank; 50 gal fuel tank
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Capable of operating in temperatures: ranging from 32 to 125 degrees f, when specified will be equiped with a winterization system; the vehicle is designed for operation at 2000 feet above sea level