TXT
묘사:
Electronic Chopper
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
8
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Tube plug
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.531 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.531 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+85.0 degrees celsius
MRC:
Indicates the type of coil used.APAG
Coil Type:
Not isolated
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, double throw
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
6.3 ac pounds per hour wet
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
Indicates the type of base furnished with the item.AWET
Base Type:
Standard base
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Not provided
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Equal
MRC:
An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
Output/input Voltage Relationship:
Equal
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
100.0 dc pounds per hour with retaining chain
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
2.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
40.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
Between 140.0 and 175.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Provided
MRC:
The size designation of the mounting base as it is commercially known and/or identified.BGRT
Base Mounting Size Designation:
Octal tube
MRC:
An indication of the arrangement of the terminal pattern.BGRW
Terminal Pattern Arrangement:
0.688 in. Diameter terminal lug circle
MRC:
The style designation indicating the configuration that most nearly corresponds to the wiring of the base connection.BGRX
Base Connection Wiring Style:
8 pin standard octal tube