부품 정보
1.000 in. Lb torque test terminals
TXT
묘사:
Induct Wire Wound Fixed Resistor
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-50.0/+50.0
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
180.000 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-3.000/+3.000
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-3.000 to 3.000
MRC:
The substance of which the heat sink is composed.AAPZ
Heat Sink Material:
Aluminum alloy
MRC:
The largest dimension of a flat rectangular/elliptical,or a chassis type of heat sink.AAQA
Heat Sink Length:
7.000 inches
MRC:
A measurement taken at right angles to the length of a flat rectangular/elliptical,or chassis type heat sink,in distinction from thickness.AAQB
Heat Sink Width:
5.000 inches
MRC:
A measurement from the bottom to the top of a chassis type heat sink,in distinction from depth.AAQD
Heat Sink Height:
2.000 inches
MRC:
A measurement of the smallest physical dimension of a heat sink,in distinction from length or width.AAQE
Heat Sink Thickness:
0.040 inches
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
25.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
275.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0/+275.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0 to 275.0
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Encased
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Eyelet
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.438 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.062 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.531 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.562 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
0.719 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
9.000 free air
MRC:
Designates the size of the relative or proportionate dimension of the mounting hole.BYML
Mounting Hole Size:
0.125 inches
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Axial terminal (s)
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
18876-9986741 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)