MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.938 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.563 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.063 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.161 in. Diameter mtg holes on 1-5/16 in. By 1-13/16 in. Mtg centers
MRC:
The basic structure of the item.ALXF
Structural Design:
Nonpile-up
MRC:
The value/s/ of direct current potential which must be applied to the item for operation,expressed in volts.APBR
Dc Operating Voltage Rating In Volts:
28.000
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Dc
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
24.000
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
3.000 amperes
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
3.700 amperes
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
28.000
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
2
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
2
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
3.700 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
105.000 milliamperes
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Clockwise
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
Spst
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
1
MRC:
An indication of the characteristic(s) of a winding.CPWM
Winding Characteristic:
Single wound tapped
MRC:
The amount of direct current resistance required to activate the coil pull-in.CPWP
Coil Pull-in Dc Resistance Rating:
7.500 ohms
MRC:
The amount of direct current resistance required to maintain operation of the coil hold-in.CPWQ
Coil Hold-in Dc Resistance Rating:
260.000 ohms
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
30.000