TXT
묘사:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield grounded to core and brought out to terminal single component
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Color coded lead
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
450.0 milliamperes ac single component 1st secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
5.5 amperes ac single component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
34.7 volts-amperes single component 2nd secondary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
59.9 volts-amperes single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
133.00 ac pounds per hour wet single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
117.00 ac pounds per hour wet single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
6.30 ac pounds per hour wet single component 2nd secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 wire lead