TXT
묘사:
Electrical Insulation Sleeving
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
Expanded Inside Diameter:
0.250 inches
Recovered Inside Diameter:
0.143 inches
Recovered Wall Thickness:
0.035 inches
MRC:
The percentage an item is rated to reduce in size upon the application of heat.AGAU
Heat Shrinkage Rating In Percent:
43.0
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Rubber, mil-r-3065
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Shrinkable
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/