MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
General purpose-nema type 1
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.125 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
575.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz and 60.0 hertz
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Automatic
MRC:
A designation indicating the size by which the item is commercially known and/or identified.AJXE
Size Designator:
00
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three mtg holes, one hole centered at top, twobottom holes 4-1/4 in. From center to center with tophole 7-3/4 in. From center line of bottom holes
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
1.500 and 2.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
220.0 ac and 240.0 ac
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Designed per nema std
MRC:
An indication of the various functional switching positions.ANRK
Switch Functional Positions:
Reset
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0