부품 정보
						Color number is drab green color number is 24052
					 
				 
						
			
			
										
					
						MRC:
						Indicates the type of mount utilized to support the item.AAXX
					 
					
						Mounting Type:
					
					
						Floor					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						52.000 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						31.750 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						42.000 inches 					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						60.0 hertz 					
				 
							
					
						MRC:
						A rating computed by dividing cooling capacity (btus)by the watts of power used to help determine the operating cost.AFPS
					 
					
						Energy Efficiency Ratio:
					
					
						4.8					
				 
							
					
						MRC:
						The value of the current flowing through the item when operated at its designed voltage,expressed in amperes.AFSS
					 
					
						Design Current Rating In Amps:
					
					
						60.0 					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Portable shelters or vans					
				 
							
					
						MRC:
						Indicates the designed use of the item.ALCD
					 
					
						Usage Design:
					
					
						Compressor, heater					
				 
							
					
						MRC:
						The value(s) of potential for which the item is rated.AMSE
					 
					
						Voltage Rating:
					
					
						Between 208.0 volts and 220.0 volts 					
				 
							
					
						MRC:
						Indicates the type of coolant used with the item.ARNA
					 
					
						Coolant Type:
					
					
						Hfc-134a					
				 
							
					
						MRC:
						The source of power which drives the item.ATJK
					 
					
						Power Source:
					
					
						Electric motor					
				 
							
					
						MRC:
						The number of electric motors provided.AWLX
					 
					
						Electric Motor Quantity:
					
					
						1					
				 
							
					
						MRC:
						The amount of refrigerant the item will hold.AWXK
					 
					
						Refrigerant Capacity:
					
					
						14.000 pounds					
				 
							
					
						MRC:
						A relative measurement of the mass of an item with respect to its density.AZQK
					 
					
						Weight:
					
					
						800.000 pounds 					
				 
							
					
						MRC:
						Indicates the type of compressor unit for which the item is designed.AZSD
					 
					
						Compressor Unit Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						The nominal capacity of the item to cool.AZSF
					 
					
						Cooling Capacity:
					
					
						2200.0 cubic feet per minute					
				 
							
					
						MRC:
						The maximum amount of air for which the item is rated,expressed in cubic feet per minute.CPZH
					 
					
						Maximum Air Capacity In Cubic Feet Per Minute:
					
					
						2200.000					
				 
							
					
						MRC:
						An indication of the rated kilowatt of the item.CTMG
					 
					
						Kilowatt Rating:
					
					
						14.0					
				 
							
					
						MRC:
						The capacity of the item to cool,expressed in british thermal units per hour.CYJE
					 
					
						Cooling Capacity In Btu Per Hour:
					
					
						65000.0 					
				 
							
					
						MRC:
						The capacity of the item to heat,expressed in british thermal units per hour.CYKM
					 
					
						Heating Capacity In Btu Per Hour:
					
					
						48000.0 					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three