부품 정보
						Otoscope & ophthalmoscope set oper btry pwr w/case
					 
				 
						
			
				
					TXT
				
				
					묘사:
				
				
					Otoscope And Ophthalmoscope Set				
			 
			
										
					
						MRC:
						The number of lamps included with the item.AEWR
					 
					
						Lamp Quantity:
					
					
						1					
				 
							
					
						MRC:
						The candlepower,or measurement of luminous intensity for which the lamp is rated,expressed in footcandles.AEWW
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The candlepower,or measurement of luminous intensity for which the lamp is rated,expressed in footcandles.AEWW
					 
					
						Lamp Candlepower Rating In Footcandles:
					
					
						300.0					
				 
							
					
						MRC:
						The voltage for which the lamp is rated for normal operation,expressed in volts.AEWX
					 
					
						Lamp Voltage Rating In Volts:
					
					
						2.5					
				 
							
					
						MRC:
						An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
					 
					
						Carrying Case:
					
					
						Provided					
				 
							
					
						MRC:
						The number of lampholders included on the item.AHGF
					 
					
						Lampholder Quantity:
					
					
						1					
				 
							
					
						MRC:
						The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
					 
					
						Furnished Items And Quantity:
					
					
						Ophthalmoscope head lamp, 1;  otoscope head lamp, 1					
				 
							
					
						MRC:
						The means used to operate the item.APHE
					 
					
						Operation Method:
					
					
						Electrical					
				 
							
					
						MRC:
						The source of power which provides the energy required for the operation of the item.AWZJ
					 
					
						Power Source:
					
					
						Battery					
				 
							
					
						MRC:
						Designates the size of the battery handle(s).CBTC
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						Designates the size of the battery handle(s).CBTC
					 
					
						Battery Handle Size:
					
					
						Medium					
				 
							
					
						MRC:
						The number of speculums provided with the item.CBTY
					 
					
						Speculum Quantity:
					
					
						1 and 1 and 1 and 1 and 10					
				 
							
					
						MRC:
						The amount of current for which the lamp is rated.CBWC
					 
					
						Lamp Current Rating:
					
					
						200.0 milliamperes					
				 
							
					
						MRC:
						Indicates the type of otoscope head provided.CMWP
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						Indicates the type of otoscope head provided.CMWP
					 
					
						Otoscope Head Type:
					
					
						Closed					
				 
							
					
						MRC:
						Indicates the type of speculum provided.CMWY
					 
					
						Speculum Type:
					
					
						Aural and aural and aural and aural and optical					
				 
							
					
						MRC:
						The element,compound,or mixture of which the speculum is fabricated,excluding any surface treatment.CMWZ
					 
					
						Err Default:
					
					
						Err default and err default and err default and err default and err default					
				 
							
					
						MRC:
						The element,compound,or mixture of which the speculum is fabricated,excluding any surface treatment.CMWZ
					 
					
						Speculum Material:
					
					
						Plastic,  thermoplastic and plastic,  thermoplastic and plastic,  thermoplastic and plastic,  thermoplastic and plastic					
				 
							
					
						MRC:
						Designates the size of the speculum.CMXB
					 
					
						Err Default:
					
					
						Err default and err default and err default and err default and err default					
				 
							
					
						MRC:
						Designates the size of the speculum.CMXB
					 
					
						Speculum Size:
					
					
						2 millimeter and 3 millimeter and 4 millimeter and 5 millimeter and adult					
				 
							
					
						MRC:
						The designation derived from the name of the designer or the use for which the ophthalmoscope head is designed.CMXC
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The designation derived from the name of the designer or the use for which the ophthalmoscope head is designed.CMXC
					 
					
						Ophthalmoscope Head Design Designation:
					
					
						May					
				 
							
					
						MRC:
						The number of lampholders included on the ophthalmoscope head.CMXD
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The number of lampholders included on the ophthalmoscope head.CMXD
					 
					
						Ophthalmoscope Head Lampholder Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of lamps included with the ophthalmoscope head.CMXF
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The number of lamps included with the ophthalmoscope head.CMXF
					 
					
						Ophthalmoscope Head Lamp Quantity:
					
					
						1					
				 
							
					
						MRC:
						The voltage for which the ophthalmoscope head lamp is rated,expressed in volts.CMXG
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The voltage for which the ophthalmoscope head lamp is rated,expressed in volts.CMXG
					 
					
						Ophthalmoscope Head Lamp Voltage Rating In Volts:
					
					
						2.5					
				 
							
					
						MRC:
						The amount of current for which the ophthalmoscope head lamp is rated.CMXJ
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The amount of current for which the ophthalmoscope head lamp is rated.CMXJ
					 
					
						Ophthalmoscope Head Lamp Current Rating:
					
					
						190.0 milliamperes					
				 
							
					
						MRC:
						The candlepower or measurement of luminous intensity for which the ophthalmoscope head lamp is rated,expressed in footcandles.CMXK
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The candlepower or measurement of luminous intensity for which the ophthalmoscope head lamp is rated,expressed in footcandles.CMXK
					 
					
						Ophthalmoscope Head Lamp Candlepower Rating In Footcandles:
					
					
						3.5					
				 
							
					
						MRC:
						The negative range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXS
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The negative range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXS
					 
					
						Ophthalmoscope Head Lens Negative Range In Diopters:
					
					
						-20.0/-1.0					
				 
							
					
						MRC:
						The positive range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXT
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The positive range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXT
					 
					
						Ophthalmoscope Head Lens Positive Range In Diopters:
					
					
						+0.5 to 20.0					
				 
							
					
						MRC:
						An indication of whether or not a zero aperture is included on the ophthalmoscope head lens.CMXW
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						An indication of whether or not a zero aperture is included on the ophthalmoscope head lens.CMXW
					 
					
						Ophthalmoscope Head Lens Zero Aperture:
					
					
						Included					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Fiber optics; as differentiated by the furnished items and quantity requirements