부품 정보
Option 908 is rack flange kit; interface is hp-ib; designed to hold up to 5 different switch and control modules: select from multiplexer, relay, form c relay, matrix switch, microwave switch module, digital i/o module, breadboard, vhf switch, 26.5 ghz signal switching (depending on modules selected); up to 50 channels, 40 configuration storage registers
TXT
묘사:
Electronic Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
425.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
89.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
292.0 millimeters
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+32.0 to 130.0 degrees fahrenheit
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Phased array antenna test fixture
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Top of cabinet/counter
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
Lcd
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Terminal block w/screw rear
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
440.0 2nd voltage
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
1 wire lead terminals external
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
132.0 1st voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Provides signal switching w/integrity and isolation needed for high performance production test systems
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
1994 hewlett packard catalog