MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
1000.0
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
6
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.2/+2.0 volts, ac single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+2.0/+20.0 volts, ac single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+20.0/+200.0 volts, ac single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+200.0/+700.0 volts, ac single indicator 4th range
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
700.0 ac