부품 정보
C/o three separate units, interfaced to one another by electrical cables; first unit is a hydraulic test bench, dim. 90.000 in. W; 50.000 in. D; 55.000 in. H; weight: 5000 lbs; the second unit is a instrumentation and control console, dim. 62.000 in. H; 40.000 in. W; 40.000 in. D; weight: 500 lbs; power: 115 v, 60 hz, single phase 20 amps; the third unit is a computer and printer, dim. On the crt are 18.000 in. H; 18.000 in. W; 7.000 in. D; the dim. On the keyboard are 3.000 in. H; 18.000 in. W; 7.000 in. D
TXT
묘사:
Electric And Hydrauli Test Stand
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
35.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Power drive unit, p/n 2022070 and 2048666, used on the f-16a/b/c/d/
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Hydraulic motor
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Aircraft hydraulic system
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor or manual
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
150.0
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Not included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
4600.0 pounds per square inch
MRC:
The maximum pressure at which the item is designed to operate.BJDW
Maximum Operating Pressure:
4600.0 pounds per square inch
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Included
MRC:
The rated flow capacity of the item.CGYL
Flow Capacity Rating:
15.8 gallons per minute
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Not included
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Aa-9.2
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to check out the leading edge flap, power drive unit
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
90-05-21
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Serd-14025