TXT
묘사:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
47.0 hertz single component and 440.0 hertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.850 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.813 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.850 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
100.00 ac volts single component all primary and 120.00 ac volts single component all primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
220.00 ac volts single component all secondary and 240.00 ac volts single component all secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 wire lead