TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal boss
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
7/8-14 unjf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
3b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Not identical with first or second end
MRC:
A narrative description of the type of end connection.ACMY
Third End Connection Type:
Threaded internal boss
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACNX
Third End Thread Size And Series/type Designator:
9/16-18 unjf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACNY
Third End Thread Class:
3b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACNZ
Third End Thread Direction:
Right-hand
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
Indicates the type of renewable seating ring in the item.ADZH
Renewable Seat Ring Type:
Pressed-in
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Bolts
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+1000.0/+2500.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic double stage
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
4500.0 pounds per square inch
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
4500.0 pounds per square inch
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -40.0 degrees fahrenheit and 160.0 degrees fahrenheit