TXT
묘사:
Steam Turbine Generator Set
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The steam pressure required to motivate the steam engine or turbine used as the prime mover.AAYL
Steam Operating Pressure:
1050.0 pounds per square inch gage
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
221.3125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
179.375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
90.4375 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The temperature of the steam required to operate an item at full capacity.AJAA
Steam Tempurature Rating:
940.0 degrees fahrenheit
MRC:
Indicates the type of stage.AWNT
Stage Type:
Multiple
MRC:
Indicates the design type characteristic/s/ of the turbine.AZBQ
Turbine Design Type:
Reaction
MRC:
Indicates the type of exhaust provided.AZBR
Exhaust Type:
Condensing
MRC:
The means provided for coupling the turbine to the generator.AZBS
Turbine To Generator Coupling Method:
Reduction gear
MRC:
The permissible temperature increase for continuous operation,at which the item is rated,expressed in degrees celsius.AZCM
Tempurature Rise Rating In Deg Celsius For Continuous Operation:
60.0