MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Oiltight
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
2
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing w/panel seal single mounting facility
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Actuator knob and cam actuated
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
120.0 lowest ac voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
120.0 lowest dc voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
600.0 highest ac voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
600.0 highest dc voltage rating at sea level
MRC:
The designation indicating the electrical configuration of a cam actuated switch including the number of switching poles or forms.CQYS
Cam Actuated Switch Contact Arrangement:
1 two circuit, double break/double make, both positions maintained 2nd switch 2nd section in-line
MRC:
The designation indicating the electrical configuration of a cam actuated switch including the number of switching poles or forms.CQYS
Cam Actuated Switch Contact Arrangement:
2 two circuit, double break/double make, both positions maintained 1st switch 1st section in-line
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
3 single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab w/screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
0.2 amperes resistive load highest dc voltage rating at sea level and 0.2 amperes inductive load highest dc voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
1.1 amperes resistive load lowest dc voltage rating at sea level and 1.1 amperes inductive load lowest dc voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
10.0 amperes resistive load highest ac voltage rating at sea level and 1.2 amperes inductive load highest ac voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
10.0 amperes resistive load lowest ac voltage rating at sea level and 6.0 amperes inductive load lowest ac voltage rating at sea level